Installation and useA general solar pump installation mainly consists of solar panels, control boxes and pumps. Solar surface pumps are used to increase water pressure. Allows water to be delivered to a higher and wider range. In sunny regions of the world, especially in remote areas where there is no electricity, solar energy is the most attractive way to supply water. In addition to water pumps and renewable energy sources, solar pumps also include all the necessary control, communication and auxiliary devices provided as a complete system. The system can be combined and adapted to any needs according to the conditions at the installation site. The energy selection and wide performance range provide greater flexibility.
The DC pump is the power source for the low pressure accumulators. It is safe and easy to operate. This is a very convenient water intake tool.
Model | Voltage (V) |
Best DC Voltage (V) |
Power (W) |
MAX. FLOW (m³/h) |
MAX.HEAD (m) |
Exit (inch) |
A solar panel |
|
open voltage | Power | |||||||
DCPMF5.5-32-48-550 | 48 | 60-90 | 550 | 5.5 | 32 | 1" | <100 | ≥800 |
DCPMF22-22-72-750 | 72 | 90-120 | 750 | 22 | 22 | 1.5" | <150 | ≥1200 |
DCPMF24-21-72-750 | 72 | 90-120 | 750 | 24 | 21 | 2" | <150 | ≥1200 |
DCPMF27-35-110-1100 | 110 | 110-150 | 1100 | 27 | 35 | 2" | <200 | ≥1650 |
DCPMF43-26-144-1500 | 144 | 144-220 | 1500 | 43 | 26 | 3" | <280 | ≥2400 |
Model: AC DC type Adaptive power: 750 - 2200 W Model: Type Adaptive power: ≤2200W
1. Low voltage and over voltage protection. 2. Overload and overvoltage protection. 3. Protection against dry pumps. 4. High temperature protection. 5. Lack of phase protection. 6. Three sets of water level switches. 7. LCD monitors. |
|
|
Model: Type D Adaptive power: ≤1100W
1. Low voltage and over voltage protection. 2. Overload and overvoltage protection. 3. Protection against dry pumps. 4. High temperature protection. 5. Lack of phase protection. 6. Three sets of water level switches. 7. LCD monitors |
|
Model: Type B Adaptive power: ≤1500W
1. Low voltage and over voltage protection. 2. Overload and overvoltage protection. 3. Protection against dry pumps. 4. High temperature protection. 5. Lack of phase protection. 6. Three sets of water level switches. 7. LCD monitors. |
|
Model: type E Adaptive power: ≤1100W
1. Low voltage and over voltage protection. 2. Overload and overvoltage protection. 3. Protection against dry pumps. 4. High temperature protection. 5. Lack of phase protection. 6. Three sets of water level switches. |
Model: Type C Adaptive power: ≤2200W
1. Low voltage and over voltage protection. 2. Overload and overvoltage protection. 3. Protection against dry pumps. 4. High temperature protection. 5. Lack of phase protection. 6. Three sets of water level switches. 7. LCD monitors. |
|
Model: Type F Adaptive power: ≤1100W
1. Low voltage and over voltage protection. 2. Overload and overvoltage protection. 3. Protection against dry pumps. 4. High temperature protection. 5. Lack of phase protection. |