Installation and useThe overall installation of solar pumps consists mainly of solar panels, control boxes and pumps. Sunny surface pumps are used to increase water pressure. 3/4 "SSD-A/D AC/DC, a deep borehole pump allows you to deliver water to a higher and wide range. In the solar regions of the world, especially in remote areas where there is no electricity, the use of solar energy is the most attractive method of water supply. In addition to water pumps and renewable energy sources, solar pumps also include all necessary control, control, they also include all the necessary control. Communication and auxiliary devices provided as a full -fledged system.
The controller can be used in single solar energy mode, the maximum current is limited to 12a, and the maximum power is monitored by the MPPT algorithm. The speed of the pump is determined by the power of solar batteries, the maximum speed of the pump, the maximum controller power and the controller temperature. When any conditions are met, the pump speed will remain current or work at a low speed.
The controller can be used in mode with one AC, and the maximum input of the AC current is limited 11a (different models may vary). The speed of the pump is determined by the input current of alternating current, the maximum speed of the pump, the maximum power of the controller and the temperature of the controller. Upon fulfilling any conditions, the pump speed will be maintained at the current speed or work at a reduced speed.
Automatic switching mode between solar energy and alternating current. Solar energy and alternating current are introduced at the same time. The default mode is solar energy.
The switching point of the input power of the solar energy is 250 watts, and if it is less than 250 W, it automatically switches to alternating current (adjustable 100 - 900 W).
The default alternating current switching time for the system is 15 minutes, and if solar energy is detected, alternating current switches to solar energy for 15 minutes. (1 - 60 minutes) can be configured.
Model | Voltage (V) |
Best DC voltage (V) |
Power (W) |
Max. Flow (m³/h) |
Max. Effort (m) |
Exit (inch) |
Cigilious (m) |
Solar panel | |
Open stress | Power | ||||||||
3SSD3.5-90-96/750-A/D | 85~265 | 60~430 | 750 | 3.5 | 90 |
1 l |
2 | <430V | ≥1100W |
3SSD3.5-128-144/1100-A/D | 85~265 | 60~430 | 1100 | 3.5 | 128 | 1" | 2 | <430V | ≥1600W |
3SSD3.5-172-192/1500-A/D | 85~265 | 60~430 | 1500 | 3.5 | 172 | 1" | 2 | <430V | ≥2200W |
3SSD4.5-73-96/750-A/D | 85~265 | 60~430 | 750 | 4.5 | 73 | 1.25" | 2 | <430V | ≥1100W |
3SSD4.5-118-144/1100-A/D | 85~265 | 60~430 | 1100 | 4.5 | 118 | 1.25" | 2 | <430V | ≥1600W |
3SSD4.5-155-192/1500-A/D | 85~265 | 60~430 | 1500 | 4.5 | 155 | 1.25" | 2 | <430V | ≥2200W |
3SSD6.5-62-96/750-A/D | 85~265 | 60~430 | 750 | 6.5 | 62 | 1.25" | 2 | <430V | ≥1100W |
3DCS6.5-93-144/1100-A/D | 85~265 | 60~430 | 1100 | 6.5 | 93 | 1.25” | 2 | <430V | ≥1600W |
3DCS6.5-125-192/1500-A/D | 85~265 | 60~430 | 1500 | 6.5 | 125 | 1.25" | 2 | <430V | ≥2200W |
4DCS5-69-96/750-A/D | 85~265 | 60~430 | 750 | 5 | 69 | 1.25" | 2 | <430V | ≥1100W |
4DCS5-110-144/1100-A/D | 85~265 | 60~430 | 1100 | 5 | 110 | 1.25" | 2 | <430V | ≥1600W |
4DCS4.5-138-192/1500-A/D | 85~265 | 60~430 | 1500 | 4.5 | 138 | 1.25" | 2 | <430V | ≥2200W |
4DCS4.5-190-280/2200-a/D | 85~265 | 60~430 | 2200 | 4.5 | 190 | 1.25” | 2 | <430V | ≥3300W |
4DCS6.5-63-96/750-A/D | 85~265 | 60~430 | 750 | 6.5 | 63 | 1.25" | 2 | <430V | ≥1100W |
4DCS6.5-87-144/1100-A/D | 85~265 | 60~430 | 1100 | 6.5 | 87 | 1.25" | 2 | <430V | ≥1600W |
4DCS6-111-192/1500-A/D | 85~265 | 60~430 | 1500 | 6 | 111 | 1.25" | 2 | <430V | ≥2200W |
4DCS6.5-160-280/2200-A/D | 85~265 | 60~430 | 2200 | 6.5 | 160 | 1.25" | 2 | <430V | ≥3300W |
4DCS9-53-96/750 A/D | 85~265 | 60~430 | 750 | 9 | 53 | 1.5" | 2 | <430V | ≥1100W |
4DCS8.5-80-144/1100-A/D | 85~265 | 60~430 | 1100 | 8.5 | 80 | 1.5" | 2 | <430V | ≥1600W |
4DCS8.5-106-192/1500-A/D | 85~265 | 60~430 | 1500 | 8.5 | 106 | 1.5" | 2 | <430V | ≥2200W |
4DCS8.5-155--280/2200-A/D | 85~265 | 60~430 | 2200 | 8.5 | 155 | 1.5" | 2 | <430V | ≥3300W |
4DCS11.5-38-96/750-A/D | 85~265 | 60~430 | 750 | 11.5 | 38 | 2" | 2 | <430V | ≥1100W |
4DCS11.5-64-144/1100-A/D | 85~265 | 60~430 | 1100 | 11.5 | 64 | 2" | 2 | <430V | ≥1600W |
4DCS11-88-192/1500-A/D | 85~265 | 60~430 | 1500 | 11 | 88 | 2" | 2 | <430V | ≥2200W |
4DCS11-125-280/2200-A/D | 85~265 | 60~430 | 2200 | 11 | 125 | 2" | 2 | <430V | ≥3300W |
4DCS16-26-96/750-A/D | 85~265 | 60~430 | 750 | 16 | 26 | 2" | 2 | <430V | ≥1100W |
4DCS16-47-144/1100-A/D | 85~265 | 60~430 | 1100 | 16 | 47 | 2" | 2 | <430V | ≥1600W |
4DCS16-70-192/1500-A/D | 85~265 | 60~430 | 1500 | 16 | 70 | 2" | 2 | <430V | ≥2200W |
4DCS16-88-280/2200-A/D | 85~265 | 60~430 | 2200 | 16 | 88 | 2" | 2 | <430V | ≥3300W |
![]() |
Model: Type of AC DC Adaptive power: 750 - 2200 watts Model: Type Adaptive power: ≤2200W
1. Protection against low voltage and overvoltage. 2. Protection against overload and overvoltage. 3. Protection against dry pumps. 4. High -temperature protection. 5. Lack of phase protection. 6. Three sets of water level switches. 7. LCD - monitors. |
![]() |
Model: Type D Adaptive power: ≤1100W
1. Protection against low voltage and overvoltage. 2. Protection against overload and overvoltage. 3. Protection against dry pumps. 4. High -temperature protection. 5. Lack of phase protection. 6. Three sets of water level switches. 7. LCD - Monitors |
![]() |
Model: Type B Adaptive power: ≤1500W
1. Protection against low voltage and overvoltage. 2. Protection against overload and overvoltage. 3. Protection against dry pumps. 4. High -temperature protection. 5. Lack of phase protection. 6. Three sets of water level switches. 7. LCD - monitors. |
![]() |
Model: type E Adaptive power: ≤1100W
1. Protection against low voltage and overvoltage. 2. Protection against overload and overvoltage. 3. Protection against dry pumps. 4. High -temperature protection. 5. Lack of phase protection. 6. Three sets of water level switches. |
![]() |
Model: Type C. Adaptive power: ≤2200W
1. Protection against low voltage and overvoltage. 2. Protection against overload and overvoltage. 3. Protection against dry pumps. 4. High -temperature protection. 5. Lack of phase protection. 6. Three sets of water level switches. 7. LCD - monitors. |
![]() |
Model: type f Adaptive power: ≤1100W
1. Protection against low voltage and overvoltage. 2. Protection against overload and overvoltage. 3. Protection against dry pumps. 4. High -temperature protection. 5. Lack of phase protection. |