Scope● Flow can reach 90L/min (5.4m3/h)
● Up to 65 meters.
Operating limit● The force of attraction can reach 9 m
● Liquid temperature up to 90 degrees.
● Maximum ambient temperature 40°C.
It is used for clean water that does not contain crushed particles, and for liquids that are not chemically aggressive to the materials from which the pumps are made. Due to their compactness, reliability and ease of use, they are suitable for domestic applications such as water distribution and low-pressure applications. For irrigation of gardens and distribution areas, pumping water from tanks and all other types of water that require pumping, air or water may be present. The pumps are equipped with shut-off valves. Pumps should be installed in a closed environment or at least protected from adverse weather conditions.
● High water level in terms of power requirements.
● Stable operation curve, relatively large changes in pressure demand, delivery speed changes less.
● High air tolerance in pump fluid.
● Capacity up to 9 meters.
● Cast iron pumps and supports treated with special anti-corrosion treatment
● When starting the pump after a long absence, the stainless steel insert prevents the impeller from clogging
● Stainless steel mechanical seal (graphite to ceramic)
● Brass wheel with radial peripheral blades
● Stainless steel shaft
● Self-priming
● Bearing C&U 304# stainless steel axle
● electric motor with copper winding
● Built-in thermal protection device for single-phase motor
● Insulation class: F
● Protection class: IPX4
● Warranty period: 1 year (subject to our general terms and conditions of sale)
NO. | DESCRIPTION | NO. | DESCRIPTION | |
1 | Pump housing | 12 | Filter screen | |
2 | Working wheel | 13 | Flow sensor | |
3 | Mechanical seal | 14 | Filler plug | |
4 | Support | 15 | Pressure switch | |
5 | Base | 16 | Pressure tank | |
6 | Fall protection device | 17 | Stator | |
7 | Carrier | 18 | Connection box | |
8 | Rotor | 19 | Condenser | |
9 | Fan | 20 | Terminal box cover | |
10 | Fan cover | 21 | Fairleigh | |
11 | Suction flange |
MODEL | POWER | DNA | DNM | Q m3/h | 0 | 0.3 | 0.6 | 0.6 | 1 | 1.2 | 1.5 | 1.8 | 2 | 2.4 | 2.7 | 3 | 3.3 | 3.6 | 3.9 | |
KW | HP | Inch | Inch | L/min | 0 | 5 | 10 | 10 | 16.7 | 20 | 25 | 30 | 33.3 | 40 | 45 | 50 | 55 | 60 | 65 | |
PW125A | 0.125 | 0.17 | 1" | 1" | H(m) | 24 | 22 | 20 | 20 | 16 | 12 | 9 | 5 | 2 | - | - | - | - | ||
PW250A | 0.25 | 0.37 | 1" | 1" | 30 | 27 | 22 | 22 | 18 | 14 | 10 | 6 | 2.1 | - | - | - | - | |||
PW370A | 0.37 | 0.5 | 1" | 1" | 36 | 35 | 29 | 29 | 20 | 15 | 10 | 7 | 2.3 | - | - | - | - | |||
PW550A | 0.55 | 0.75 | 1" | 1" | 50 | 45 | 40 | 40 | 36 | 33 | 30 | 24 | 19 | 14 | 9 | 6 | 2 | |||
PW750A | 0.75 | 1 | 1" | 1" | 58 | 53 | 48 | 48 | 41 | 35 | 31 | 25 | 20 | 15 | 10 | 7 | 2 |