Application and installationThey are recommended to be used for pumping clean water without worn particles, and the liquids are not chemically aggressive to the materials from which the pumps are made.
AWZB Self-Priming Pump are designed for domestic use, especially for combined small automatic pressure devices for water supply and irrigation.
Pumps must be installed in enclosed areas or at least prevent inclement weather conditions.
• Load up to 8 m
• Liquid temperature up to + 40°C
• Ambient temperature up to + 90°C
• Maximum. Working pressure: 6 bar
• Pump housing: cast iron (HT200)
• Electrical supports: aluminum
• Wheel; Brass
• Axle: 45# steel, AlSl 416 stainless steel if required
• Mechanical seal: ceramic
• Electric motor: single phase 220 V - 50 Hz, charged container and thermal overload fuse.
• Allowed voltage fluctuations more than 10% or less
• Insulation: B
• Protection: IP44
• Flow up to 60 l / min (3.6 m3 / h)
• Head height 50 meters
Model | Input power | Q(m³/h) | 0 | 0.9 | 1.2 | 1.5 | 1.8 | 2.1 | 2.4 | 2.7 | 3.6 | 4.2 | |||
KW | HP | Q(L/min) | 0 | 15 | 20 | 25 | 30 | 35 | 40 | 45 | 60 | 70 | |||
1AWZB 125 | 0.125 | 0.17 | H(m) | 24 | 11 | 7 | 3.7 | ||||||||
1AWZB 250 | 0.25 | 0.34 | 28 | 16 | 12 | 8 | 3.4 | ||||||||
1AWZB 370 | 0.37 | 0.5 | 32 | 21 | 17 | 25 | 7.6 | 3 | |||||||
1AWZB 550 | 0.55 | 0.75 | 38 | 27.3 | 23.3 | 19 | 15 | 10.6 | 5.7 | ||||||
1AWZB 750 | 0.75 | 1 | 44 | 34 | 30 | 26 | 22 | 17 | 12 | 7 | |||||
1.5AWZB 1100 | 1.1 | 1.5 | 50 | 44 | 40.4 | 36.9 | 32.9 | 28.8 | 24.3 | 19 | 12.6 | 5 |
Performance graph n = 2850 RPM
Model | Input/output | N.W | L×W×H | |||
(inches) | (Kg) | (mm) | ||||
1AWZB 125 | 1"×1" | 9 | 280×225×305 | |||
1AWZB 250 | 1"×1" | 10 | 280×225×305 | |||
1AWZB 370 | 1"×1" | 11 | 280×225×305 | |||
1AWZB 550 | 1"×1" | 13 | 310×235×305 | |||
1AWZB 750 | 1"×1" | 14.5 | 345×250×335 | |||
1.5AWZB 1100 | 1½"×1½" | 18.5 | 360×280×370 |
Numbers | Notes | Numbers | Notes | Numbers | Notes | Numbers | Notes | ||||||||
1 | Latch | 13 | Pump housing | 25 | Fan | 37 | Pressure switch | ||||||||
2 | Spring washer | 14 | Fall protection | 26 | Fan cover | 38 | Latch | ||||||||
3 | Latch | 15 | Pump bracket | 27 | Latch | 39 | Pressure Capacity | ||||||||
4 | "O" Ring | 16 | Relationship | 28 | Spring washer | 40 | Pressure Vessel Label | ||||||||
5 | Wheel cover | 17 | Key | 29 | Electric cable | 41 | "O" Ring | ||||||||
6 | Tablet with wheel cover | 18 | Stator | 30 | Terminal box nut | 42 | Loading plug | ||||||||
7 | Wheel | 19 | Rotor | 31 | Cable support | 43 | "O" Ring | ||||||||
8 | pump housing tablet | 20 | Housing with wound stator | 32 | Condenser | 44 | check valve | ||||||||
9 | Clamp ring | 21 | Open ring | 33 | Latch | 45 | Surface coating | ||||||||
10 | Mechanical seal | 22 | Support leg | 34 | Connection box | 46 | Latch | ||||||||
11 | "O" Ring | 23 | Pilot's hat | 35 | Tablet | 47 | Spring washer | ||||||||
12 | Latch | 24 | Latch | 36 | In Fairlea |